Session log 2026-04-03: WO import, 7B support, PG migration started
- 33K work orders imported, 2.27M records linked - 7B exact-match formatter added (31 params, 120VAC, Packing Check List) - TXT formatting refined to match QB TAB positions exactly - PostgreSQL 18 installed on AD2, database created - SQL Server Express uninstalled - Full Dataforth audit document generated Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
80
Test Datasheets/weekend-update-draft.md
Normal file
80
Test Datasheets/weekend-update-draft.md
Normal file
@@ -0,0 +1,80 @@
|
||||
Subject: Test Datasheets - Weekend Update: All 73 Quatronix Sheets Generated, Work Order Search Live
|
||||
|
||||
John, Ken,
|
||||
|
||||
Quick update on progress since Friday's email. The pipeline is significantly further along.
|
||||
|
||||
## Quatronix Customer Issue - RESOLVED
|
||||
|
||||
All 73 requested datasheets have been generated (TXT + PDF). The last holdout was SCM5B49-05 (SN 177000-15) — the 5B49DATA.DAT spec file was empty, but John pointed us to 5B49_2.DAT which had the data. All 73 files are ready to send to Peter/Ginger.
|
||||
|
||||
## Model Spec Coverage Expanded
|
||||
|
||||
We went from 751 model specs to 1,470+ by loading additional spec databases:
|
||||
|
||||
| Spec File | Family | Models |
|
||||
|-----------|--------|--------|
|
||||
| 5BMAIN.DAT | SCM5B | 481 |
|
||||
| 5B45DATA.DAT | SCM5B (freq/counter) | 56 |
|
||||
| DB5B48.DAT | SCM5B (multi-bandwidth) | 3 |
|
||||
| 5B49_2.DAT | SCM5B (sample & hold) | 15 |
|
||||
| 8BMAIN.DAT | 8B | 148 |
|
||||
| DSCOUT.DAT | DSCA (output) | 23 |
|
||||
| DSCMAIN4.DAT | DSCA (input) | 391 |
|
||||
| SCTMAIN.DAT | DSCT | 103 |
|
||||
| 7BMAIN.DAT | SCM7B | 276 |
|
||||
|
||||
If there are additional spec files we're missing, let me know the paths and we'll add them.
|
||||
|
||||
## SCM7B Support Added
|
||||
|
||||
The 7B product family is now fully supported in the datasheet generator:
|
||||
- 31 test parameters (vs 20 for SCM5B)
|
||||
- Correct header ("SCM" prefix prepended to model name)
|
||||
- 120VAC Withstand / Hi-Pot (skipped for 7BPT models)
|
||||
- "Packing Check List" with blank fields (vs pre-marked checkboxes on 5B/8B)
|
||||
- "Tested by" and "QC" signature lines
|
||||
- Note: The 7B DAT format (single CSV line) doesn't include individual accuracy test points, so the accuracy table is omitted. Only the Final Test Results section is generated from DAT data.
|
||||
|
||||
## Work Order Search & Linking
|
||||
|
||||
Imported all 33,745 work order status reports from the test station Reports folders:
|
||||
- 63,263 individual test lines parsed (serial number, model, pass/fail, date/time, station)
|
||||
- 2.27 million test records linked to their work orders
|
||||
|
||||
In the web app (http://192.168.0.6:3000):
|
||||
- New "Work Order #" search field — enter a WO number to find all associated test records
|
||||
- Click the WO number in any record's detail view to see the full work order:
|
||||
- All serial numbers tested under that WO
|
||||
- Pass/fail status for each (including retests)
|
||||
- Test program and version used
|
||||
- Test station and timestamps
|
||||
- New work order reports are automatically imported when synced from the NAS
|
||||
|
||||
## Datasheet Formatting Refined
|
||||
|
||||
Compared generated datasheets against originals from the DFWDS archive and fixed column alignment to match the QuickBASIC output:
|
||||
- TAB positions match exactly (parameter names, measured values, spec limits, pass/fail)
|
||||
- Number formatting matches QB PRINT USING (right-justified, correct decimal places)
|
||||
- STR$() behavior replicated (leading space for positive numbers, dropped leading zeros)
|
||||
- Spec limit formatting matches (e.g., "+/- .03 %" not "+/- 0.03 %")
|
||||
|
||||
## View Button Updated
|
||||
|
||||
The "SHEET" button in the web app now shows a styled HTML page that matches the PDF/TXT layout — white page, monospace font, same column alignment. Includes Print and Download PDF buttons.
|
||||
|
||||
## Infrastructure
|
||||
|
||||
- Created domain service account (INTRANET\svc_testdatadb) for the TestDataDB Windows service — resolves the file permission issues we were hitting
|
||||
- Added STAGE folder sync to the NAS sync script — TXT datasheets from DOS machines will now be pulled to AD2 automatically
|
||||
- Work order report import added to sync script — new reports are ingested automatically every 15 minutes
|
||||
|
||||
## Still Open
|
||||
|
||||
1. **Website upload** — The old Uploader.aspx endpoints are dead. Need to determine the new upload mechanism for dataforth.com.
|
||||
2. **STAGE backlog** — ~8,100 TXT files on the NAS from DOS machines need to be processed (script ready, haven't run it yet).
|
||||
3. **Pending ForWeb export** — ~845K records in the database don't have TXT files in For_Web yet (mostly 7B and older records). Can batch-export as needed.
|
||||
|
||||
Let me know if you need anything else.
|
||||
|
||||
Mike
|
||||