DATAFORTH CORPORATION Phone: (520) 741-1404
|
||||
3331 E. Hemisphere Loop Fax: (520) 741-0762
|
||||
Tucson, AZ 85706 USA email: info@dataforth.com
|
||||
|
||||
TEST DATA SHEET
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
Date: 05-15-2018
|
||||
Model: SCM5B38-05
|
||||
SN: 129093-16
|
||||
|
||||
ACCURACY TEST
|
||||
|
||||
Calculated Measured
|
||||
Vin (mV) Vout (V) Vout (V)* Error (%) Status
|
||||
========== ========== ========== ========= ========
|
||||
-20.000 -5.000 -5.000 -0.005 PASS
|
||||
-9.999 -2.500 -2.499 +0.002 PASS
|
||||
-0.001 -0.000 +0.001 +0.016 PASS
|
||||
+10.001 +2.500 +2.502 +0.018 PASS
|
||||
+20.000 +5.000 +5.000 +0.003 PASS
|
||||
|
||||
FINAL TEST RESULTS
|
||||
|
||||
Parameter Measured Value Specification Status
|
||||
======================= =============== ===================== ======
|
||||
Supply Current, Nom 29.0 mA < 75 mA PASS
|
||||
Supply Current, Max 130.6 mA < 194 mA PASS
|
||||
Output Resistance 22 ohms < 55 ohms PASS
|
||||
Exc. Voltage 10.001 V 10.0+/-0.003 V PASS
|
||||
Exc. Load Reg. 5 ppm/mA +/-11 ppm/mA PASS
|
||||
Vout Reg. w/ Load 0.0 % +/-0.1 % PASS
|
||||
Exc. Current Limit 54.4 mA < 63 mA PASS
|
||||
Linearity 0.010 % +/- 0.03 % PASS
|
||||
Accuracy 0.018 % +/- 0.08 % PASS
|
||||
Supply Sensitivity 0.8 uV/% +/- 2.4 uV/% PASS
|
||||
Frequency Response 29.2 dB 27+/-7 dB PASS
|
||||
Output Noise 566 uVrms < 4000 uVrms PASS
|
||||
240 VAC Withstand PASS
|
||||
Hi-Pot PASS
|
||||
_______________________________________________________________________
|
||||
Check List
|
||||
|
||||
Module Appearance: __X__ Mounting Screw: __X__
|
||||
|
||||
Pins Straight: __X__ Module Header: __X__
|
||||
|
||||
It is hereby certified that the above product is in conformance with
|
||||
all requirements to the extent specified. This product is not
|
||||
authorized or warranted for use in life support devices and/or systems.
|
||||
|
||||
* NIST traceable calibration certificates support Measured Value data.
|
||||
Calibration services are available through ANSI/NCSL Z540-1 and
|
||||
ISO Guide 25 Certified Metrology Labs.
|
||||