Subject: Test Datasheets - Weekend Update: All 73 Quatronix Sheets Generated, Work Order Search Live John, Ken, Quick update on progress since Friday's email. The pipeline is significantly further along. ## Quatronix Customer Issue - RESOLVED All 73 requested datasheets have been generated (TXT + PDF). The last holdout was SCM5B49-05 (SN 177000-15) — the 5B49DATA.DAT spec file was empty, but John pointed us to 5B49_2.DAT which had the data. All 73 files are ready to send to Peter/Ginger. ## Model Spec Coverage Expanded We went from 751 model specs to 1,470+ by loading additional spec databases: | Spec File | Family | Models | |-----------|--------|--------| | 5BMAIN.DAT | SCM5B | 481 | | 5B45DATA.DAT | SCM5B (freq/counter) | 56 | | DB5B48.DAT | SCM5B (multi-bandwidth) | 3 | | 5B49_2.DAT | SCM5B (sample & hold) | 15 | | 8BMAIN.DAT | 8B | 148 | | DSCOUT.DAT | DSCA (output) | 23 | | DSCMAIN4.DAT | DSCA (input) | 391 | | SCTMAIN.DAT | DSCT | 103 | | 7BMAIN.DAT | SCM7B | 276 | If there are additional spec files we're missing, let me know the paths and we'll add them. ## SCM7B Support Added The 7B product family is now fully supported in the datasheet generator: - 31 test parameters (vs 20 for SCM5B) - Correct header ("SCM" prefix prepended to model name) - 120VAC Withstand / Hi-Pot (skipped for 7BPT models) - "Packing Check List" with blank fields (vs pre-marked checkboxes on 5B/8B) - "Tested by" and "QC" signature lines - Note: The 7B DAT format (single CSV line) doesn't include individual accuracy test points, so the accuracy table is omitted. Only the Final Test Results section is generated from DAT data. ## Work Order Search & Linking Imported all 33,745 work order status reports from the test station Reports folders: - 63,263 individual test lines parsed (serial number, model, pass/fail, date/time, station) - 2.27 million test records linked to their work orders In the web app (http://192.168.0.6:3000): - New "Work Order #" search field — enter a WO number to find all associated test records - Click the WO number in any record's detail view to see the full work order: - All serial numbers tested under that WO - Pass/fail status for each (including retests) - Test program and version used - Test station and timestamps - New work order reports are automatically imported when synced from the NAS ## Datasheet Formatting Refined Compared generated datasheets against originals from the DFWDS archive and fixed column alignment to match the QuickBASIC output: - TAB positions match exactly (parameter names, measured values, spec limits, pass/fail) - Number formatting matches QB PRINT USING (right-justified, correct decimal places) - STR$() behavior replicated (leading space for positive numbers, dropped leading zeros) - Spec limit formatting matches (e.g., "+/- .03 %" not "+/- 0.03 %") ## View Button Updated The "SHEET" button in the web app now shows a styled HTML page that matches the PDF/TXT layout — white page, monospace font, same column alignment. Includes Print and Download PDF buttons. ## Infrastructure - Created domain service account (INTRANET\svc_testdatadb) for the TestDataDB Windows service — resolves the file permission issues we were hitting - Added STAGE folder sync to the NAS sync script — TXT datasheets from DOS machines will now be pulled to AD2 automatically - Work order report import added to sync script — new reports are ingested automatically every 15 minutes ## Still Open 1. **Website upload** — The old Uploader.aspx endpoints are dead. Need to determine the new upload mechanism for dataforth.com. 2. **STAGE backlog** — ~8,100 TXT files on the NAS from DOS machines need to be processed (script ready, haven't run it yet). 3. **Pending ForWeb export** — ~845K records in the database don't have TXT files in For_Web yet (mostly 7B and older records). Can batch-export as needed. Let me know if you need anything else. Mike