DATAFORTH CORPORATION Phone: (520) 741-1404 3331 E. Hemisphere Loop Fax: (520) 741-0762 Tucson, AZ 85706 USA email: info@dataforth.com TEST DATA SHEET ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Date: 05-15-2018 Model: SCM5B38-05 SN: 129093-16 ACCURACY TEST Calculated Measured Vin (mV) Vout (V) Vout (V)* Error (%) Status ========== ========== ========== ========= ======== -20.000 -5.000 -5.000 -0.005 PASS -9.999 -2.500 -2.499 +0.002 PASS -0.001 -0.000 +0.001 +0.016 PASS +10.001 +2.500 +2.502 +0.018 PASS +20.000 +5.000 +5.000 +0.003 PASS FINAL TEST RESULTS Parameter Measured Value Specification Status ======================= =============== ===================== ====== Supply Current, Nom 29.0 mA < 75 mA PASS Supply Current, Max 130.6 mA < 194 mA PASS Output Resistance 22 ohms < 55 ohms PASS Exc. Voltage 10.001 V 10.0+/-0.003 V PASS Exc. Load Reg. 5 ppm/mA +/-11 ppm/mA PASS Vout Reg. w/ Load 0.0 % +/-0.1 % PASS Exc. Current Limit 54.4 mA < 63 mA PASS Linearity 0.010 % +/- 0.03 % PASS Accuracy 0.018 % +/- 0.08 % PASS Supply Sensitivity 0.8 uV/% +/- 2.4 uV/% PASS Frequency Response 29.2 dB 27+/-7 dB PASS Output Noise 566 uVrms < 4000 uVrms PASS 240 VAC Withstand PASS Hi-Pot PASS _______________________________________________________________________ Check List Module Appearance: __X__ Mounting Screw: __X__ Pins Straight: __X__ Module Header: __X__ It is hereby certified that the above product is in conformance with all requirements to the extent specified. This product is not authorized or warranted for use in life support devices and/or systems. * NIST traceable calibration certificates support Measured Value data. Calibration services are available through ANSI/NCSL Z540-1 and ISO Guide 25 Certified Metrology Labs.