--- name: Test datasheet pipeline map description: Full pipeline from DOS test stations through NAS sync, DFWDS processing, to web upload at dataforth.com. Includes current status of each stage. type: project --- ## Complete Pipeline (5 stages) ### Stage 1: Test Stations (QuickBASIC on DOS) - 64 test stations (TS-1 through TS-30, plus L/R variants, TS-GURU, TS-TOM) - QuickBASIC programs generate test data -> local C:\STAGE on each DOS PC - Data flows to D2TESTNAS (NAS at 192.168.0.9, rsync daemon port 873, module "test" -> /data/test) ### Stage 2: NAS <-> AD2 Sync (Sync-FromNAS-rsync.ps1) - Runs every 15 min via scheduled task on AD2 - PULL: .DAT files + .TXT reports from NAS -> C:\Shares\test\TS-XX\LOGS\\ and \Reports\ - Imports .DAT files into TestDataDB via C:\Shares\testdatadb\database\import.js - PUSH: Software updates (ProdSW, UPDATE.BAT, DEPLOY.BAT) from AD2 -> NAS for DOS machines - Log types: 5BLOG, 7BLOG, 8BLOG, DSCLOG, SCTLOG, VASLOG, PWRLOG, HVLOG - Script: C:\Shares\test\scripts\Sync-FromNAS-rsync.ps1 - Log: C:\Shares\test\scripts\sync-from-nas.log (rotated at 10MB, 5 archives) ### Stage 3: DFWDS.exe (Dataforth Website Datasheet program, v2015) - Source exe: \\AD1\Engineering\ENGR\ATE\Test Datasheets\DFWDS\DFWDS.exe - Config: C:\DFWDS\DFWDS_NAMES.TXT (hardcoded path in exe) - Reads X:\Test_Datasheets (X: = \\ad2\webshare) - Validates files, renames DOS-encoded filenames to serial number format - Valid -> X:\For_Web (~501K files), Invalid -> X:\Bad_Datasheets (~18K files) - Logs -> X:\Datasheets_Log (daily logs since 2014) - Operations: COUNT, LISTALL, LISTBAD, LISTRENAME, INPLACE, WEBMOVE ### Stage 4: TestDataSheetUploader (VB.NET, .NET 4.7.2) - Source: \\AD1\Engineering\ENGR\ATE\Test Datasheets\TestDataSheetUploader\ - Syncs files to www.dataforth.com via 3 HTTP services: - Uploader.aspx, DirectoryManifest.aspx, DeleteFile.aspx - Credentials: DataforthWebShare / Data6277 - Only uploads files modified in current year - Compares local vs server manifest (filename, size, last-write-time) - Deletes server files that no longer exist locally - Author: "hoffm" (Hoffman) ### Stage 5: PDF generation - X:\For_Web_PDF has ~4,773 PDFs (separate process, origin unclear) ## X: Drive Layout (\\ad2\webshare) - X:\Test_Datasheets — incoming datasheets (staging for DFWDS) - X:\For_Web — validated/renamed datasheets (501K+ files) - X:\For_Web_PDF — PDF versions (4.7K files) - X:\Bad_Datasheets — invalid files (18K files) - X:\Datasheets_Log — DFWDS operation logs ## Datasheet Format - Plain text, ~50 lines - Header: Dataforth Corporation address/phone - Fields: Date, Model (e.g. SCM5B41-03), SN (e.g. 178439-1) - Accuracy test table (Vin, Calculated Vout, Measured Vout, Error%, Status) - Final test results (Supply Current, Output Resistance, Linearity, Accuracy, etc.) - Filename format: {SN}.txt (e.g. 178439-1.txt) ## TestDataDB - Node.js/SQLite app at C:\Shares\testdatadb\ - PM2-managed via start-server.bat - Scheduled task "TestDataDB Server" runs at system startup (currently DISABLED) - Provides web UI and API for querying test data - Import script: C:\Shares\testdatadb\database\import.js ## Known Gaps (as of 2026-03-27) 1. MISSING LINK: How do .TXT reports get from C:\Shares\test\TS-XX\Reports\ to X:\Test_Datasheets? May need to build this. Clues may exist in Engineering share. 2. DFWDS config (C:\DFWDS\DFWDS_NAMES.TXT) missing — wiped in crypto attack. Check Haubner machine D: drive for backup of visible shares. 3. TestDataSheetUploader not deployed/scheduled on AD2 — needs production config 4. TestDataDB Server task disabled — should be operational **Why:** Reconstructing this pipeline after AD2 crypto wipe. Manufacturing is actively producing test data (files arriving daily) but downstream processing (DFWDS, web upload) is broken. **How to apply:** Priority is restoring the full pipeline end-to-end. Check Haubner D: for DFWDS config backup. Look in ENGR share for clues about the Reports->Test_Datasheets transfer mechanism.