Extends the Test Datasheet Pipeline on AD2:C:\Shares\testdatadb to
generate web-published datasheets for the SCMVAS-Mxxx (obsolete) and
SCMHVAS-Mxxxx (replacement) High Voltage Input Module product lines.
Both are tested either with the existing TESTHV3 software (production
VASLOG .DAT logs) or in Engineering with plain .txt output.
Key changes on AD2 (all deployed 2026-04-12 with dated backups):
- parsers/spec-reader.js: getSpecs() returns a `{_family:'SCMVAS',
_noSpecs:true}` sentinel for SCMVAS/SCMHVAS/VAS-M/HVAS-M model prefixes
so the export pipeline does not silently skip them for missing specs.
- templates/datasheet-exact.js: new Accuracy-only template branch
(generateSCMVASDatasheet + helpers) that mirrors the existing shipped
format byte-for-byte. Extraction regex covers both QuickBASIC STR$()
output formats: scientific-with-trailing-status-digit (98.4% of
records) and plain-decimal (1.6% of records above QB's threshold).
- parsers/vaslog-engtxt.js (new): parses the Engineering-Tested .txt
files in TS-3R\LOGS\VASLOG\VASLOG - Engineering Tested\. Filename SN
regex strips optional trailing 14-digit timestamp; in-file "SN:"
header is the authoritative source when the filename is malformed.
- database/import.js: LOG_TYPES grows a VASLOG_ENG entry with
subfolder + recursive flags. Pre-existing 7 log types keep their
implicit recursive=true behaviour (config.recursive !== false).
importFiles() routes VASLOG_ENG paths before the generic loop so a
VASLOG - Engineering Tested/*.txt path does not mis-dispatch to the
multiline parser.
- database/export-datasheets.js: VASLOG_ENG records are written
verbatim via fs.copyFileSync(source_file, For_Web/<SN>.TXT) for true
byte-level pass-through, with a graceful raw_data fallback when the
source file is no longer on disk.
Deploy outcome:
- 27,503 SCMVAS/SCMHVAS datasheets rendered (27,065 from scientific +
438 from plain-decimal PASS lines, post-patch rerun)
- 434 Engineering-Tested .txt files pass-through-copied to For_Web
- 0 errors across both batches
Repo layout added here:
- scmvas-hvas-research/: discovery artifacts (source .BAS, hvin.dat,
sample .DAT + .txt, binary-format notes, IMPLEMENTATION_PLAN.md)
- implementation/: staged final code + deploy helpers + local test
harness + per-step verification scripts
- backups/pre-deploy-20260412/: independent local snapshot of the 4
AD2 files replaced, pulled byte-for-byte before deploy
All helper scripts fetch the AD2 password at runtime from the SOPS
vault (clients/dataforth/ad2.sops.yaml). None of the committed files
contain the plaintext credential. Known vault-entry hygiene issue
(stale shell-escape backslash before the `!`) is documented in the
fetcher comments and stripped at read-time; flagged separately for
cleanup.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
34 lines
1.5 KiB
Plaintext
34 lines
1.5 KiB
Plaintext
Dataforth Corporation Phone number: (520) 741-1404
|
|
3331 E. Hemisphere Loop Fax: (520) 741-0762
|
|
Tucson, AZ 85706 USA Email: info@dataforth.com
|
|
|
|
|
|
|
|
|
|
TEST DATA SHEET
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Date: 10/04/2023
|
|
Model: SCMHVAS-M0200
|
|
SN: 166590-1
|
|
FINAL TEST RESULTS
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
Parameter Measured Value Specification Status
|
|
================ ============== ============= ======
|
|
Accuracy 0.007% +/- 0.03% PASS
|
|
|
|
_______________________________________________________________________
|
|
Check List
|
|
|
|
Module Appearance: __X__ Mounting Screw: __X__
|
|
|
|
Pins Straight: __X__ Module Header: __X__
|
|
|
|
It is hereby certified that the above product is in conformance with
|
|
all requirements to the extent specified. This product is not
|
|
authorized or warranted for use in life support devices and/or systems.
|
|
|
|
* NIST traceable calibration certificates support Measured Value data.
|
|
Calibration services are available through ANSI/NCSL Z540-1 and
|
|
ISO Guide 25 Certified Metrology Labs.
|
|
|
|
|