STARTNET.BAT Path Fix - DOS Update System

Date: 2026-01-20 Issue: Files reference old path C:\NET\STARTNET.BAT instead of C:\STARTNET.BAT Severity: MEDIUM - Causes deployment to call outdated STARTNET version Status: FIXED and DEPLOYED


Problem Description

During deployment on TS-4R, the system attempted to call C:\NET\STARTNET.BAT which is an old version. The current, correct version is at C:\STARTNET.BAT (root of C: drive).

Affected Operations:

  • AUTOEXEC.BAT - Calls wrong STARTNET during boot
  • Error messages - Show wrong path to user
  • DEPLOY.BAT - Documentation references wrong path

Impact:

  • Machines may load outdated network configuration
  • Users may attempt to run wrong version when troubleshooting
  • Inconsistent network drive mapping behavior

Root Cause

All batch files were created with references to C:\NET\STARTNET.BAT based on older Dataforth DOS machine configurations. However, the production machines have the current version at C:\STARTNET.BAT in the root directory.

The C:\NET\STARTNET.BAT version is outdated and should not be used.


Files Fixed

Changed references from C:\NET\STARTNET.BAT to C:\STARTNET.BAT in:

  1. AUTOEXEC.BAT

    • Line 37: IF EXIST C:\STARTNET.BAT CALL C:\STARTNET.BAT
    • Line 75: Error message showing correct path
  2. DEPLOY.BAT

    • Line 133: Documentation text updated
  3. UPDATE.BAT

    • Lines 71-72: Error message showing correct path
  4. CTONW.BAT

    • Line 35: Error message showing correct path
  5. CHECKUPD.BAT

    • Line 50: Error message showing correct path
  6. NWTOC.BAT

    • Line 34: Error message showing correct path
  7. DOSTEST.BAT

    • Lines 41, 42, 92, 117, 192: All references updated (5 occurrences)

Deployment Status

Deployed to AD2: 2026-01-20

Locations:

  • \\192.168.0.6\C$\Shares\test\COMMON\ProdSW\ - All 7 files
  • \\192.168.0.6\C$\Shares\test\_COMMON\ProdSW\ - All 7 files

Sync Status:

  • AD2→NAS sync runs every 15 minutes
  • Files will be available on T:\COMMON\ProdSW\ within 15 minutes
  • Machines will receive updates on next NWTOC run or reboot

Testing Checklist

Before full rollout, verify on TS-4R:

  1. Check STARTNET.BAT location:

    DIR C:\STARTNET.BAT
    DIR C:\NET\STARTNET.BAT
    

    Expected: C:\STARTNET.BAT exists, C:\NET\STARTNET.BAT may be old version

  2. Verify AUTOEXEC.BAT calls correct version:

    TYPE C:\AUTOEXEC.BAT | FIND "STARTNET"
    

    Expected: Shows C:\STARTNET.BAT not C:\NET\STARTNET.BAT

  3. Test network startup:

    C:\STARTNET.BAT
    

    Expected: Network starts, T: and X: drives map successfully

  4. Verify error messages show correct path:

    REM Disconnect network first
    NET USE T: /DELETE
    C:\BAT\UPDATE
    

    Expected: Error message shows C:\STARTNET.BAT not C:\NET\STARTNET.BAT


Combined Fixes in UPDATE.BAT v2.1

UPDATE.BAT now includes TWO fixes:

  1. XCOPY /D parameter error (2026-01-20 morning)
  2. STARTNET.BAT path correction (2026-01-20 afternoon)

Version: 2.1 Changes:

  • Removed invalid /D flag from XCOPY command
  • Changed C:\NET\STARTNET.BAT to C:\STARTNET.BAT

Also deployed today:

  • UPDATE.BAT v2.1 (XCOPY fix + STARTNET path fix)
  • Root UPDATE.BAT (redirect script, 170 bytes)

File Structure:

T:\ (root)
├── UPDATE.BAT → Redirect to T:\COMMON\ProdSW\DEPLOY.BAT
│
└── COMMON\ProdSW\
    ├── DEPLOY.BAT - Deployment installer
    ├── UPDATE.BAT - Backup utility (v2.1)
    ├── AUTOEXEC.BAT - Startup template
    ├── STARTNET.BAT - Network startup (v2.0)
    ├── NWTOC.BAT - Download updates
    ├── CTONW.BAT - Upload test data
    ├── CHECKUPD.BAT - Check for updates
    └── DOSTEST.BAT - Test deployment

Verification on DOS Machine

When machines get the update, verify correct path is being used:

  1. After reboot, check AUTOEXEC.BAT:

    TYPE C:\AUTOEXEC.BAT | FIND "STARTNET"
    
  2. Verify network starts correctly:

    DIR T:\
    DIR X:\
    
  3. If network fails, manually run:

    C:\STARTNET.BAT
    

    (Should work since AUTOEXEC now calls correct path)


Rollback Plan

If issues occur with the new path:

  1. Verify C:\STARTNET.BAT exists and is current version

  2. If C:\STARTNET.BAT is missing:

    • Copy from T:\COMMON\ProdSW\STARTNET.BAT
    • Or revert to C:\NET\STARTNET.BAT temporarily
  3. If C:\NET\STARTNET.BAT is needed:

    • Revert AUTOEXEC.BAT to call C:\NET\STARTNET.BAT
    • But verify why C:\STARTNET.BAT is missing

Notes

Why C:\STARTNET.BAT vs C:\NET\STARTNET.BAT?

The batch files should reference wherever the CURRENT version is on the production machines. User confirmed that C:\STARTNET.BAT is the correct, current location and C:\NET\STARTNET.BAT is outdated.

File placement flexibility:

  • STARTNET.BAT can be in either location
  • AUTOEXEC.BAT just needs to reference the correct location
  • The version at C:\STARTNET.BAT is version 2.0 (last modified 2026-01-19)

Success Criteria

  • Machines boot and call C:\STARTNET.BAT (not C:\NET\STARTNET.BAT)
  • Network starts successfully on boot
  • T: and X: drives map correctly
  • Error messages show correct path (C:\STARTNET.BAT)
  • No references to C:\NET\STARTNET.BAT in production files

Deployment Summary:

  • 7 files fixed
  • 14 total deployments (7 to COMMON, 7 to _COMMON)
  • All deployments successful
  • Ready for production use

Next Session: Monitor TS-4R after sync completes, verify UPDATE.BAT backup works correctly