Dataforth Test-Data Chain — Ground-Truth Audit (AD2)

Auditor: Autonomous read-only agent (Claude), launched via RMM Host: AD2 / 192.168.0.6 — Windows Server 2019 Standard 10.0.17763 (booted 2026-06-18) Audit window: 2026-07-01 ~16:3216:55 UTC Mode: STRICTLY READ-ONLY. No file was created, modified, moved, renamed, or deleted except this deliverable (C:\Users\sysadmin\ad2-audit\FINDINGS.md). No git/service/task/DB writes were performed. The Postgres DB was queried inside BEGIN TRANSACTION READ ONLY; the NAS was accessed via read-only rsync --list-only and ssh only.

Reading guide. The supplied briefing was explicitly ~3 months stale ("treat as hints only"). Several premises are now wrong on the ground (SQLite → PostgreSQL; drive letters; which sync script runs; which scripts are deployed vs abandoned). Each such correction is called out. Every material claim cites live evidence (file + size + mtime, log line, DB count, or NAS listing) so other models can re-verify.


1. Executive summary

The outbound test-results pipeline (DOS stations → NAS → AD2 → database → web delivery) is operational and current — data landed in the database as recently as 2026-07-01 13:41 UTC (same day as this audit). The inbound spec/software-distribution pipeline is partially broken: the master specification .DAT files are not distributed to the DOS stations, which is a precise, reproducible root cause for Syncro #32489. A single stray file (TS-21\ProdSW) makes the 15-minute sync report ERRORS on every run, masking real failures. The primary datastore has been migrated from SQLite to PostgreSQL 18 and the web-delivery mechanism from the broken ASP.NET/For_Web path to an HTTP API uploader; neither change is reflected in the briefing.

Severity-ranked findings

# Sev Finding Status
F1 HIGH NWTOC.BAT v5.0 distributes no master spec .DAT files to stations (by design: "removed DATA folder copies"). Root cause of Syncro #32489. Confirmed
F2 HIGH Deployed NWTOC.BAT v5.0 and CTONWTXT.BAT v2.3 use COPY /Y, not a native MS-DOS 6.22 switch. If stations run true 6.22, the station downloader silently fails entirely. Confirmed in code; needs station verification
F3 MED C:\Shares\test\TS-21\ProdSW is a file, not a directory → rsync push fails (exit 3) on every 15-min run; sync status is permanently ERRORS. Confirmed
F4 MED Server-side datasheet generation reads specs from testdatadb\specdata\ — a frozen 2026-03-27 snapshot, not the live engineering masters (e.g. 5BMAIN.DAT updated 2026-06-26). Confirmed
F5 MED Plaintext credentials (NAS root SSH password, rsync daemon password, Postgres app password) hard-coded in scripts under C:\Shares\test\scripts\ and ...\testdatadb\database\db.js. Confirmed
F6 LOW For_Web web-delivery output is dead since 2026-05-11; superseded by the API uploader. Legacy ASP.NET path effectively retired but not documented as such. Confirmed
F7 LOW Duplicate/abandoned batch drafts in C:\Shares\test\ root use NT-only constructs (FOR /F, SET /A, CALL :label, %~dpnF) that would fail on 6.22. Not in the boot path, but a confusion/cleanup hazard. Confirmed
F8 LOW NAS share littered with junk/stray entries (.DS_Store, NUL), files named BAT/C, case-dup 5b39data.dat/5B39DATA.DAT, old v1.0 scripts at share root). Confirmed
F9 INFO SSH key auth to NAS root@192.168.0.9 is not configured/broken (publickey denied); the production sync does not use it (uses rsync daemon), so impact is nil today. Confirmed

2. As-verified chain topology (corrections in bold)

NAS = D2TESTNAS = 192.168.0.9 (a Linux box; uname blocked by SSH auth but rsync daemon + DOS AUTOEXEC confirm identity). Serves SMB shares \\D2TESTNAS\test (→ Linux /data/test) and \\D2TESTNAS\datasheets, plus an rsync daemon on port 873, module test/data/test.

Stations (DOS 6.22, QuickBASIC ATE — BRUN45.EXE, MENUX.EXE present on NAS) map T: = \\D2TESTNAS\test and X: = \\D2TESTNAS\datasheets (per deployed AUTOEXEC.BAT v3.0, lines 4546).

Correction to briefing: On AD2 itself, T: is not the NAS — net use shows T: → \\ad2\e-drive (AD2's own engineering share) and X: → \\ad2\webshare. The DOS-station T:/X: mappings above apply on the stations, not on AD2. AD2 reaches the NAS only over SSH/rsync to 192.168.0.9, never via a drive letter.

OUTBOUND (test results):
  DOS station  C:\ATE\{5B,7B,8B,DSC,HV,PWR,SCT,VAS}LOG\*.DAT
    │  (boot: AUTOEXEC → CTONW.BAT v5.0, plain COPY)
    ▼
  NAS  /data/test/TS-XX/LOGS/<type>/*.DAT   +  /TS-XX/Reports/*.TXT  +  /STAGE/TS-XX/*.TXT
    │  (AD2 scheduled task "Sync-FromNAS", every 15 min, rsync --remove-source-files)
    ▼
  AD2  C:\Shares\test\TS-XX\LOGS\...        → node import.js / import-work-orders.js / import-all-stage.js
    ▼
  PostgreSQL 18  db "testdatadb"  (test_records, work_orders, work_order_lines, *_quarantine)
    │  (export-datasheets.js / render-datasheet.js → text datasheets;  upload-to-api.js → website)
    ▼
  X:\webshare\Test_Datasheets (current)      [ For_Web = legacy, dead since 2026-05-11 ]
  + HTTP API upload (active: 472,290 records flagged api_uploaded)

INBOUND (specs / software):
  Engineering master specs  C:\Shares\test\Ate\ProdSW\{5B,7B,8B,DSC,SCT}DATA\*MAIN*.DAT
    │  (AD2→NAS push, rsync --update:  reaches NAS OK)
    ▼
  NAS  /data/test/Ate/ProdSW/<type>DATA/*.DAT   ← 5BMAIN.DAT present & current (83,200 b, 2026-06-26)
    │  (station boot: NWTOC.BAT v5.0)
    ▼
  ✗  NWTOC v5.0 copies only  T:\COMMON\ProdSW\*.BAT → C:\BAT  and  T:\Ate\ProdSW\*.EXE → C:\ATE.
     It copies NO *.DAT.  →  Master specs never reach the stations.   ← ROOT CAUSE (F1)

3. INBOUND spec distribution — root cause of Syncro #32489 (F1)

The deployed downloader is T:\COMMON\ProdSW\NWTOC.BAT, version 5.0 (C:\Shares\test\COMMON\ProdSW\NWTOC.BAT, 972 bytes, mtime 2026-03-16; identical copy verified on NAS COMMON/ProdSW/NWTOC.BAT 972 b). Its own header states the cause verbatim:

Line 3:  REM Version: 5.0 - Added EXE copy, removed DATA folder copies (avoid cyclic overwrites)
Line 18: COPY /Y T:\COMMON\ProdSW\*.BAT C:\BAT
Line 22: COPY /Y T:\Ate\ProdSW\*.EXE C:\ATE
Line 26: COPY /Y T:\COMMON\NET\*.* C:\NET

There is no .DAT copy anywhere in NWTOC v5.0. The "removed DATA folder copies" change is exactly what broke master-spec refresh on the stations.

The specs exist and are current everywhere except the stations, which makes the impact concrete:

  • Engineering master on AD2: C:\Shares\test\Ate\ProdSW\5BDATA\5BMAIN.DAT = 83,200 b, mtime 2026-06-26 11:43.
  • Same file on the NAS (pushed successfully): /data/test/Ate/ProdSW/5BDATA/5BMAIN.DAT = 83,200 b, 2026-06-26 11:43 (rsync listing).
  • NWTOC v5.0 will never fetch it → stations keep whatever 5BMAIN.DAT they last received.

Other live masters (all under Ate\ProdSW\<type>DATA\), showing engineering is editing them: 7BMAIN.DAT 47,940 b 2025-06-10; 8BMAIN.DAT 24,124 b 2024-10-14; DSCMAIN4.DAT 65,508 b 2026-01-16; SCTMAIN.DAT 20,933 b 2024-08-21. (There is also a non-8.3 8BMAIN(2013-02-15).DAT that the sync correctly skips — see F8.)

Even the older NWTOC drafts never distributed COMMON master specs. The abandoned v1.0 draft (C:\Shares\test\NWTOC.BAT) copies machine-specific T:\%MACHINE%\ProdSW\*.DAT (its lines 165167) but never T:\COMMON\ProdSW\*.DAT, and COMMON\ProdSW contains zero .DAT files anyway (verified: 22 files, all .BAT). So there is no version of the download tool that pushes the shared master specs to stations. The recommended fix (F1 in §11) must add a DATA copy, it cannot merely "restore" one.


4. MS-DOS 6.22 command-structure analysis (focus area)

A crucial distinction the briefing blurs: the scripts that actually run on stations live in COMMON\ProdSW\ (and are mirrored to the NAS), NOT in the C:\Shares\test\ root. The root-level NWTOC.BAT/CTONW.BAT/CHECKUPD.BAT/STAGE.BAT are abandoned earlier drafts and are riddled with NT-cmd-only constructs; the deployed versions were deliberately cleaned. Judging DOS-compatibility off the root drafts would be a mistake.

4a. Deployed scripts (station boot path) — DOS-6.22 status

Boot flow (deployed AUTOEXEC.BAT v3.0): STARTNET.BATNWTOC.BAT (download) → CTONW.BAT (upload) → CD \ATEmenux.

Deployed script Ver DOS 6.22 verdict Notes
AUTOEXEC.BAT 3.0 Clean SET, IF EXIST T:\*.*, CALL, GOTO only
STARTNET.BAT (not read; maps T:/X:) out of scope, recommend spot-check
NWTOC.BAT 5.0 COPY /Y risk (F2) see below
CTONW.BAT 5.0 Clean uses plain COPY (no /Y); silently overwrites, correct on 6.22
CTONWTXT.BAT 2.3 COPY /Y risk (F2) COPY /Y C:\STAGE\*.TXT T:\STAGE\%MACHINE%
DEPLOY.BAT 2.4 Clean header: "Use COPY instead of XCOPY (DOS 6.22 compatibility)"
CHECKUPD.BAT 1.4 Clean header: "removed CALL :label subroutines"; uses SET FLAG= + GOTO, no SET /A
STAGE.BAT (rev) Clean but orphaned line 133 now TYPE ... >> (was FOR /F "skip=1"); however NWTOC v5.0 never calls it, so the AUTOEXEC.NEW/CONFIG.NEW auto-update mechanism is dead code

4b. F2 — COPY /Y is not a native MS-DOS 6.22 switch (HIGH, needs station confirmation)

MS-DOS 6.22's internal COPY supports /A /B /V only. The /Y (and /-Y) overwrite-suppression switch was introduced in MS-DOS 7.0 (Windows 95). On a genuine 6.22 COMMAND.COM, COPY /Y src dst returns Invalid switch - /Y and performs no copy.

  • Deployed NWTOC.BAT v5.0 uses COPY /Y for all three of its copy steps (batch files, EXEs, NET files). If the stations are truly 6.22, NWTOC copies nothing — a broader failure than F1 (stations would receive no batch/EXE/NET updates at all).
  • Deployed CTONWTXT.BAT v2.3 likewise uses COPY /Y.
  • The upload path survives regardless, because CTONW.BAT v5.0 uses plain COPY — which is why test data keeps flowing (see §5) even if NWTOC is silently dead.

This cannot be confirmed from AD2 (the stations were not in scope/reachable for this audit). It is the single highest-value item for a cross-checker to verify on a station: run VER (confirm the exact DOS version) and test COPY /Y NUL C:\x.txt. If 6.22, replace COPY /YCOPY in NWTOC.BAT and CTONWTXT.BAT. If the stations are actually MS-DOS 7.x (Win9x DOS mode), /Y is fine and F2 is a non-issue — the fact that F1's "removed DATA copies" note exists implies NWTOC has been running successfully, which is weak evidence the stations tolerate /Y; still worth a definitive check.

4c. F7 — Abandoned root-level drafts (LOW, cleanup)

C:\Shares\test\NWTOC.BAT (v1.0), CTONW.BAT (v1.2), CHECKUPD.BAT (v1.0), STAGE.BAT all use constructs invalid on 6.22 and should be removed to avoid someone deploying them by mistake:

  • FOR /F "skip=1 delims=" %%L IN (C:\AUTOEXEC.BAT)FOR /F is NT-only (root STAGE.BAT line 133).
  • SET /A SYSFILE=SYSFILE+1SET /A arithmetic is NT-only (root CHECKUPD.BAT).
  • CALL :CHECK_COMMON_FILE and GOTO :EOF — call-to-label / :EOF are NT-only (root CHECKUPD.BAT).
  • %%~dpnF, %~nx1 — tilde path modifiers are NT-only (root CTONW.BAT line 189; root CHECKUPD.BAT line 187).
  • T: 2>NUL and ... >NUL 2>NUL — handle-specific 2> stderr redirection is NT-only; 6.22 COMMAND.COM supports only >, >>, <.

(Note: the classic IF EXIST T:\NUL directory test and CHOICE /C:YN are valid 6.22 and appear in these drafts — but the items above are not.)

4d. Other 6.22 considerations (INFO)

  • Environment space. Deployed AUTOEXEC.BAT/DEPLOY.BAT set MACHINE, PATH, TEMP, TMP. 6.22's default environment is 256 bytes and can overflow ("Out of environment space"). Ensure each station's CONFIG.SYS has SHELL=C:\DOS\COMMAND.COM C:\DOS /E:512 /P. CONFIG.SYS is station-local and was not inspectable from AD2 — recommend spot-check.
  • 8.3 filenames. The whole chain assumes 8.3 names; the sync explicitly skips non-8.3 files (see §5). Any master spec saved with a long name (e.g. 8BMAIN(2013-02-15).DAT) is invisible to DOS anyway.

5. Sync engine (AD2 ↔ NAS)

Correction to briefing: the scheduled task Sync-FromNAS runs Sync-FromNAS-rsync.ps1, not Sync-FromNAS.ps1. Verified from the task action: powershell.exe -ExecutionPolicy Bypass -NonInteractive -File C:\Shares\test\scripts\Sync-FromNAS-rsync.ps1. The non-rsync Sync-FromNAS.ps1 (per-file SCP, NAS root creds) is dormant. The live status header _SYNC_STATUS.txt confirms it — it reads ... Status (rsync) with WO Reports Imported/STAGE TXT Files fields that exist only in the rsync script's template.

  • Task: Sync-FromNAS, State Running, trigger every 15 min from 2026-01-20; LastRunTime 2026-07-01 09:30, LastTaskResult = 1 (non-zero, i.e. errors), NumberOfMissedRuns 0. (Task-scheduler clock/report lags the log, which shows runs continuing to 13:41.)
  • Mechanism: rsync daemon rsync://rsync@192.168.0.9/test, PULL uses --archive --include=*.DAT --exclude=* --remove-source-files per station per log-type; imports pulled files via node import.js. PUSH uses --update with an 8.3 --files-from allowlist.

F3 — permanent ERRORS from one stray file (MED)

Every run today (39 runs) ends Sync complete: PULL=n, PUSH=0, Errors=1. The single error is identical each run:

2026-07-01 09:35:28 :   ERROR: rsync push failed (exit 3): rsync.exe : rsync:
   [sender] change_dir "/cygdrive/c/Shares/test/TS-21/ProdSW/" failed: Not a directory

Ground truth: C:\Shares\test\TS-21\ProdSW is a fileMode -a----, 79,116 bytes, mtime 2026-06-26; its sibling LOGS\ and Reports\ are directories. The file's first bytes are an MZ header containing the string 7BMAIN4 — i.e. a misplaced DOS executable dropped where a ProdSW directory is expected. The rsync PUSH loop (Sync-FromNAS-rsync.ps1 line 723, Push-DirectoryToNAS $prodSwPath) cannot change_dir into a file → exit 3 → errorCount=1 → status ERRORS forever. This is cosmetic to data flow but masks any new, real error and keeps LastTaskResult=1.

PULL side is healthy (evidence outbound works)

Today's per-run PULL counts include 12,623 (06:44), 806 (09:21), 661 (08:50), most others 0 (because --remove-source-files drains the NAS, so steady-state is 0). The big pulls are backlog flushes. Import into Postgres is landing — see §6.

The per-run PUSH log also shows the expected 8.3 skips (not errors), e.g. Skipping (non-8.3): Copy of QB.EXE, _KDSCOUT1.EXE, 8BDATA/8BMAIN(2013-02-15).DAT, PWRDATA/8BPWR - (2012-09-13).DAT.

NAS read-only verification

rsync --list-only confirmed: module root /data/test (3,730 entries), 62 TS-* station folders, COMMON/ProdSW/ holding the v5.0 deployed set (NWTOC 972 b, CTONW 1,504 b, CTONWTXT 392 b, DEPLOY 4,142 b, CHECKUPD 3,239 b), Ate/ProdSW/5BDATA/5BMAIN.DAT current (83,200 b 2026-06-26), and STAGE/ per-station folders (TS-11L/TS-11R updated 2026-07-01 06:35 — fresh STAGE TXT activity).

F9 — SSH root key auth to NAS is broken (INFO)

ssh -i C:\Users\sysadmin\.ssh\id_ed25519 root@192.168.0.9Permission denied (publickey,password). The dormant SCP script relies on this key; the live rsync path does not, so there is no operational impact today, but the SCP fallback would fail if ever re-enabled.


6. Database & generation

Correction to briefing: the datastore is PostgreSQL 18.3, not SQLite. database\db.js: "PostgreSQL Database Abstraction Layer … Replaces better-sqlite3 singleton with pg.Pool." package.json v2.0.0 depends on pg ^8.20.0 (no better-sqlite3). Service postgresql-18 is Running (PID 6044, listening ::1:5432). The old SQLite file survives only as an archive: database\archive\testdata.db = 4,401,168,384 bytes (4.4 GB), mtime 2026-04-03 — the migration cutover date (migrate-data.js, schema-pg.sql). All queries below were run inside BEGIN TRANSACTION READ ONLY.

Row counts (db testdatadb, schema public):

Table Rows
test_records 475,553
work_orders 34,149
work_order_lines 64,051
test_records_quarantine 3 (clean; dedup healthy)
test_records_dedup_bak_20260415 (backup table, stale artifact)

Recency / pipeline liveness (from test_records):

  • max(import_date) = 2026-07-01 13:41:53 UTC (day of audit); max(test_date) = 2026-06-30.
  • Imported last 24h: 111; last 7d: 623. work_orders last import 2026-07-01 13:43 UTC.
  • Per log_type last import: 5BLOG & 7BLOG → 07-01 (current); DSCLOG → 06-30; 8BLOG,PWRLOG → 06-26; VASLOG,SCTLOG → 06-18. (8B/PWR/VAS/SCT trailing is plausibly just no production on those lines; not proven to be a fault — worth a glance.)

Web-delivery stage flags (test_records): api_uploaded_at set on 472,290 / 475,553 (99.3%), with 33,908 uploaded in the last 7 days → the HTTP API uploader (upload-to-api.js) is the active delivery path. forweb_exported_at = 300,781 and datasheet_exported_at = 298,155 are legacy counters that have stopped growing.

F4 — server-side spec staleness (MED)

parsers/spec-reader.js line 19: const DEFAULT_SPEC_DIR = path.join(__dirname, '..', 'specdata') and line 366 defaults to it. So the server generates datasheets from C:\Shares\testdatadb\specdata\, whose spec DATs are a 2026-03-27 snapshot (e.g. specdata\5BMAIN.DAT 83,200 b 2026-03-27 vs engineering's Ate\ProdSW\5BDATA\5BMAIN.DAT 83,200 b 2026-06-26; specdata\5B49DATA.DAT is 0 bytes). specdata\ is not fed from the engineering masters by any automation observed. Net effect: both the station-side and the server-side spec refreshes are stale/manual. If a spec limit changed after 2026-03-27, generated datasheets may use outdated limits even though the outbound data pipeline is otherwise healthy.

F6 — For_Web output dead since 2026-05-11 (LOW)

X:\webshare\For_Web = 7,517 files, newest 2026-05-11 09:53, oldest 2023-10-04. X:\webshare\Test_Datasheets newest = 2026-06-29 11:09 (WO 180554). Generation now targets Test_Datasheets + API; the ASP.NET/For_Web path is effectively retired (consistent with the briefing's "largely broken/404"). Recommend documenting For_Web as deprecated so it is not mistaken for a live output.


7. F5 — Security: plaintext credentials (MED)

Hard-coded secrets discovered in-place (already plaintext on this host; not copied into any vault by this read-only audit — flagged for rotation + proper vaulting):

  • C:\Shares\test\scripts\Sync-FromNAS-rsync.ps1 L2224: rsync daemon user rsync / password IQ2…19.
  • C:\Shares\test\scripts\Sync-FromNAS.ps1 (dormant) L1922: NAS root SSH password Pap…nas, plus host key.
  • C:\Shares\testdatadb\database\db.js L1121: Postgres testdatadb_app / password DfT…26! (also the process-env default).

Recommend: rotate all three, move to environment/DPAPI/SOPS, and scrub the scripts. (These are also world-readable via the test SMB share.)


8. F8 — Share hygiene / clutter (LOW)

  • NAS /data/test root carries junk and stale duplicates: .DS_Store, ._.DS_Store, a 0-byte file literally named NUL), stray files named BAT and C, a case-duplicate pair 5b39data.dat + 5B39DATA.DAT, and old v1.0 NWTOC.BAT (8,925 b) / CTONW.BAT (11,341 b) / CHECKUPD.BAT (6,495 b) at the share root (superseded by COMMON\ProdSW).
  • AD2 C:\Shares\test\ root mirrors the mess: files named -, C, X, TS-21.stray-dat-file, TS-27.old.file, plus ~10 Sync-FromNAS.ps1.backup-* copies and abandoned v1.x batch drafts.
  • C:\Shares\testdatadb\ has dozens of _*.js/*.bak-* scratch/debug files intermixed with production code — recommend relocating to a scratch/ folder for clarity (no functional impact).

9. Discrepancies vs the supplied briefing (for cross-checkers)

  1. Datastore: briefing says SQLite database\testdata.db; reality is PostgreSQL 18 (testdatadb). SQLite is a 4.4 GB archive from the 2026-04-03 cutover.
  2. Which sync script runs: briefing implies Sync-FromNAS.ps1; the task runs Sync-FromNAS-rsync.ps1.
  3. T: on AD2: briefing implies T: = NAS staging; on AD2 T: = \\ad2\e-drive. NAS is reached by SSH/rsync to 192.168.0.9.
  4. import.js path: exists at database\import.js (referenced correctly), not repo root.
  5. CTONWTXT "gap" (prior memory): CTONWTXT.BAT is invoked — CTONW.BAT v5.0 line 30 CALL C:\BAT\CTONWTXT.BAT. Its output (T:\STAGE\%MACHINE%) is now largely redundant given server-side generation, but the call is live and STAGE TXT still flows (TS-11L/R today).
  6. NWTOC "v5.0" identity: the deployed downloader header literally reads Version: 5.0; the v1.0 file in the share root is an abandoned draft. Syncro #32489's "v5.0" reference is correct and points at COMMON\ProdSW\NWTOC.BAT.

10. What I could NOT verify (scope/reachability limits)

  • Station-side reality: no station was inspected. F2 (COPY /Y on true 6.22), CONFIG.SYS environment sizing, STARTNET.BAT, and the actual VER are station-confirmable only. This is the top cross-check.
  • NAS OS/uname/df: SSH root auth denied (F9); only rsync-daemon listings were available. NAS free space not measured.
  • Website endpoints: the API uploader's server (target of upload-to-api.js) was not probed (out of read-only scope / avoid outward calls). Only the DB api_uploaded_at flags evidence success.
  • 8B/PWR/VAS/SCT import lull: observed but not root-caused (could be normal no-production).

11. Recommendations (NONE applied — read-only audit)

Priority order. All are proposals; no change was made.

  1. (F1, HIGH) Restore master-spec distribution to stations. Add a DATA copy to NWTOC.BAT — e.g. COPY T:\Ate\ProdSW\5BDATA\*.DAT C:\ATE\5BDATA (and 7B/8B/DSC/SCT), or a dedicated NWSPEC.BAT. Must be a pull to a distinct local dir to avoid the "cyclic overwrite" the v5.0 note was avoiding — i.e. don't push station DATA back up. Verify against how the ATE program locates *MAIN*.DAT.
  2. (F2, HIGH) Confirm DOS version on a station; if 6.22, replace COPY /YCOPY in NWTOC.BAT v5.0 (3 lines) and CTONWTXT.BAT v2.3. If MS-DOS 7.x, document that and close F2.
  3. (F3, MED) Remove/relocate the stray C:\Shares\test\TS-21\ProdSW file (it is a misplaced 7BMAIN4-ish EXE). Then verify sync returns Errors: 0. Consider hardening Push-DirectoryToNAS to skip a ProdSW that is not a container (the PULL side already guards this pattern; the PUSH side does not).
  4. (F4, MED) Feed testdatadb\specdata\ from the engineering masters (scheduled copy from Ate\ProdSW\<type>DATA\*MAIN*.DAT, with 8.3 + non-empty checks; note 5B49DATA.DAT is currently 0 bytes), or point spec-reader.js DEFAULT_SPEC_DIR at the live master directory.
  5. (F5, MED) Rotate & vault the rsync, NAS-root, and Postgres passwords; remove plaintext from scripts; tighten test share ACLs.
  6. (F6/F7/F8, LOW) Cleanup: mark For_Web deprecated; delete the abandoned v1.x root batch drafts and NAS root duplicates/junk; move _*.js/*.bak-* scratch out of the app dir.
  7. (F9, INFO) Either fix id_ed25519 auth for root@192.168.0.9 or delete the dormant SCP script so the two sync scripts don't diverge.

12. Evidence appendix — commands run (all read-only)

  • Host/shares: hostname, Get-NetIPAddress, Get-CimInstance Win32_OperatingSystem, net use, Get-SmbShare, Get-PSDrive.
  • Scheduled task: Get-ScheduledTask/Info Sync-FromNAS (Action/Trigger/LastResult).
  • Batch/PS sources read in full: deployed COMMON\ProdSW\{NWTOC,CTONW,CTONWTXT,AUTOEXEC,DEPLOY,CHECKUPD,STAGE}.BAT; abandoned root drafts test\{CTONW,NWTOC,CHECKUPD,STAGE,UPDATE}.BAT; scripts\Sync-FromNAS.ps1, scripts\Sync-FromNAS-rsync.ps1; testdatadb\database\db.js, package.json, parsers\spec-reader.js (grep).
  • Logs: scripts\sync-from-nas.log (today's ERROR + summary lines), _SYNC_STATUS.txt.
  • DB (read-only txn): information_schema table/column introspection; COUNT(*), max(import_date/test_date), interval filters, per-log_type aggregation; version(), current_database().
  • NAS (read-only): ssh -o BatchMode=yes (auth denied, recorded); rsync --list-only on module root, COMMON/ProdSW/, Ate/ProdSW/5BDATA/, STAGE/.
  • Filesystem: Get-ChildItem/Get-Item for sizes/mtimes across C:\Shares\{test,TestDataDB,webshare}; Get-Content -TotalCount to identify the TS-21\ProdSW stray by header.

End of report.