sync: auto-sync from HOWARD-HOME at 2026-06-24 12:49:35
Author: Howard Enos Machine: HOWARD-HOME Timestamp: 2026-06-24 12:49:35
This commit is contained in:
30
.claude/memory/feedback_verify_live_before_acting.md
Normal file
30
.claude/memory/feedback_verify_live_before_acting.md
Normal file
@@ -0,0 +1,30 @@
|
||||
---
|
||||
name: feedback_verify_live_before_acting
|
||||
description: Always pull LIVE current data before acting on (or alarming about) a hardware/infra finding — wiki/session-logs are point-in-time snapshots that go stale
|
||||
metadata:
|
||||
type: feedback
|
||||
---
|
||||
|
||||
Before acting on, or raising alarm about, any hardware/infrastructure state — **pull live current
|
||||
data first and lead with THAT, not the wiki or a recalled fact.** The wiki, session logs, and memory
|
||||
are point-in-time snapshots; a "broken/degraded/failing" flag may have changed by the time you read it.
|
||||
This matters most for **hard-to-reverse or money-spending actions** (drive swaps, hardware pulls,
|
||||
parts purchases, "it's down" escalations).
|
||||
|
||||
**Why:** 2026-06-24 — the Cascades CS-SERVER wiki carried a `[CRITICAL] RAID degraded / failing
|
||||
drive` flag from 2026-06-15. Acting on it, **SSDs were purchased** and Howard went onsite ready to
|
||||
hot-swap the "failing" drive. A **live Dell OMSA `omreport` query (via the RMM agent)** then showed
|
||||
the OS mirror had **self-recovered** (the flaky drive dropped out and re-synced after a power cycle):
|
||||
all 5 disks Online/Ok, all LEDs green, and the "5th unused drive" was actually the **global hot
|
||||
spare**. Acting on the 9-day-stale flag nearly pulled a healthy drive and wasted a drive purchase.
|
||||
Howard's directive: "always go with live current data to make sure our findings are real."
|
||||
|
||||
**How to apply:**
|
||||
- For Dell servers: `omreport storage controller|vdisk|pdisk controller=0` + `omreport system esmlog`
|
||||
via the RMM agent (OMSA reads the controller directly — authoritative). iDRAC/Redfish is the
|
||||
out-of-band equivalent (no iDRAC skill yet; creds not vaulted as of 2026-06-24).
|
||||
- Windows `Get-PhysicalDisk`/`Get-Disk` shows only the VIRTUAL disks as "Healthy" even when a member
|
||||
is degraded — it CANNOT see the array; never conclude RAID health from the OS view alone.
|
||||
- For any infra claim sourced from the wiki/a recalled fact: re-verify the specific file/flag/host is
|
||||
still true before recommending action. State the data's timestamp and source.
|
||||
- See [[reference_rmm_drive_map_explorer_refresh]] for the OMSA-via-RMM pattern context.
|
||||
Reference in New Issue