Read-only Phase 0 baseline extended to floors 5/6 (MemCare). Findings:
- MemCare = same 3 diseases as 1-4 but untreated (2.4 at full power, not
over-thinned; all 5GHz on DFS+80MHz; min-RSSI off everywhere; 6GHz dark;
Shelby .218 stuck on 2.4 at Nurse Station).
- 5GHz static non-DFS channel-plan dry-run: co-channel pairs 19 -> 0 (kills
auto on all non-mesh APs; relieves AP 103/505 as fall-out).
- 2.4 1/6/11 re-color NEGATIVE right now (22 -> 28); defer until 2b restores
a stable Medium-power radio set.
- 7-day hour-of-day traffic: ~600 clients 24/7 (only ~10% swing); trough
01:00-04:00 MST. Change window decided: 2 AM start.
No changes applied. Survey stalled 68/74 (re-run before any 5GHz channel apply).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
--full recompile. Folds the 4 repo-rewrite-recovered docs into the article
(master plan, voice QoS design, voice-quality diagnostic, RF/voice session log)
while preserving all existing depth. Key corrections/additions:
- Voice VLAN 30 cutover now COMPLETE: 8 AudioCodes (.224-.231) added; prior
compile had them 0/8 pending. AudioCodes needed a physical power-cycle
(externally powered/PoE off; controller bounce is a no-op).
- Poly fleet is 28 not 22 (6 stragglers still off VOICE).
- Voice quality is an RF problem on the Poly WiFi phones, not the VLAN move
(per-phone diagnostic; Lauren .202 50% retry -> locked to AP 103; AP 103
5GHz saturated; coverage gaps rooms 515/210/204).
- 6 GHz dark root-caused (CSCNet not broadcasting 6g).
- Measured WAN1 upload ~522 Mbps -> voice QoS is insurance, RF is the fix.
- New Patterns: Voice QoS design, Network Optimization Master Plan,
Decisions-2026-06-18 (non-DFS only; no dedicated voice SSID).
- Active Work / History / HIPAA reconciled to the complete cutover.
Live Syncro unchanged (55.75 hrs, 0 tickets, 29 assets). Synthesis was
deliberate surgical enrichment (diff-reviewed), not a blind regenerate.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Refresh-mode update. Live Syncro values unchanged (55.75 prepaid hrs, 0 open
tickets as of 2026-06-18). Added the 4 docs recovered in c2e5f4f to sources:
RF/voice optimization session log, network-optimization master plan, phase-1
voice QoS design, and the 2026-06-18 voice-quality diagnostic.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The 2026-06-18 repo restructure (history rewrite + project->submodule split)
dropped these 4 Cascades files from the new clone. Copied byte-identical from
the pre-cutover claudetools.old clone (md5-verified):
- docs/network/network-optimization-master-plan.md
- docs/network/phase1-voice-qos-design.md
- reports/2026-06-18-voice-quality-diagnostic.md
- session-logs/2026-06/2026-06-18-howard-cascades-rf-voice-optimization-plan.md
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The push handlers set the button to 'skipped' then immediately ran search(), which
re-rendered the inspector and wiped the text — so a skipped publish flashed and
vanished (looked like nothing happened). Replace with persistent toasts that state the
outcome explicitly: Published / already up-to-date / Push failed / and for a skip,
'<model> isn't renderable yet, so nothing was sent.' Only refresh the row on an actual
publish so the message isn't clobbered. Same for the multi-select Re-push summary.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Results pane now fills the full width on load (the empty ~500px inspector no longer
reserves space). Inspector column expands when a record opens; Esc closes it back to
full-width results. Same behavior at the 1180px breakpoint.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
coord.py 'lock release' takes the lock ID; the documented path form no-ops
and strands the lock until TTL. Capture the lock ID at claim (5.0), release
it in Phase 6. Recurring friction (errorlog 2x).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
New MSP tool — single-assessor consult intake. Stack: PHP + MySQL on the IX cPanel
host, gated by Cloudflare Access (only mike@azcomputerguru.com; app re-checks the
Cf-Access-Authenticated-User-Email header).
- app/questions.json — risk-ordered question framework (9 sections); each field tagged
source=syncro/rmm/scan/ask so the consult asks only what a human knows and the
post-meeting scan fills the technical reality.
- app/index.php — wizard UI: Syncro phone lookup -> prefill, section rail with live
progress, importance-colored question cards, in-meeting 365/Google consent links,
review + export.
- app/api.php — Syncro lookup-by-phone, save/load/list, consent-URL generation (reuses
the read-only Security Investigator app bfbc12a4-...), HTML export.
- app/schema.sql, config.sample.php, DEPLOY.md, README.md.
Consent links let the client approve read-only 365/Google access during the consult so
the audit scan runs afterward. Read-only by design (reads Syncro, generates consent; no
tenant writes).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Probed each of the 1,578 unuploaded PASS serials across the 54 validated DSCA33/45
models against the Hoffman API (stale inventory -> can't trust api_uploaded_at as
"absent"). 1,452 were absent (404), 126 already live. Pushed ONLY the absent set:
created=1452 updated=0 unchanged=0 errors=0 — zero overwrites of pristine originals,
the handoff's hard requirement.
Tools: publish-dsca3345-gap.js (absent-only Created publish), validate-dsca3345.js.
Net: DSCA33/45 effort complete — 54/56 models live + validated; 2 rounding-boundary
holdouts and 2 no-original models (24 units) remain null.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Cracked the DSCA33/45 accuracy-block numeric formatting against the Hoffman originals
(formatAccuracyLineDSCA3345):
- mA-output models store calc (and, for DSCA45, meas) in AMPS -> x1000 to display mA;
DSCA33 stores meas already in display unit (NOT scaled), DSCA45 scales both.
- DSCA33 (AC-RMS): stim/calc/meas UNSIGNED, error signed; stim is AC input to 3 dp.
- DSCA45 (frequency): stim is an UNSIGNED integer Hz; calc/meas/error SIGNED.
- Math.fround on accuracy values (QB single-precision rounding), matching the Final-Test fix.
Final-Test fixes too: leading-zero drop only when the value overflows QB's 6-char field
("-0.0005"->"-.0005", but "-0.750" keeps its zero); spec-less section sub-heads
(Zero-Crossing Input / TTL Input) render with NO status (only Withstand/Hi-Pot get PASS);
DSCA33 prints a "Check List" header after the underline.
slotmap-from-hoffman.js (new): derive slotMaps for the models the staged multi-unit
derivation couldn't (vintage-heavy) by matching the Hoffman _srcSerial original's
Final-Test measured values (at display precision) to the DB STATUS entries. Recovered
all 13 remaining DSCA33 models.
Validation (validate-dsca3345.js, content-normalized byte-compare vs live Hoffman
originals): 54 of 56 models PASS and are marked validated:true (the render gate).
2 holdouts (DSCA33-04A, DSCA33-1891) each have ONE accuracy cert at a rounding boundary
where fround rounds opposite to the original; left UNvalidated -> still render null
(safe). DSCA33-1948 + DSCA45-1746 (24 units) have no Hoffman original.
Gate now OPEN for the 54 validated models (render live); 2 holdouts + the no-template
pair stay null. Publishing the api_uploaded_at IS NULL gap next (never re-pushes the
~7,157 pristine originals).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Per the 5070 handoff (DSCA33-45-HOFFMAN-RECOVERY): the lost DSCA33/45 specs are
recoverable from Hoffman, not John. Wired the mined dsca33-45-templates.json (56
models) into the renderer:
- datasheet-exact.js: load DSCA3345_TEMPLATES; for family DSCA, the Hoffman-mined
template takes PRECEDENCE over the stale staged-extraction entry (which shadowed 25
models with accOut "?"/no accHeader). Emit the verbatim 2-line accHeader for these
families (Vin (mVAC)/Iin (AAC)/Frequency (Hz), Output (VDC)/(mADC)). Per-model
`validated` GATE: a DSCA33/45 model renders only after byte-matching its Hoffman
original; until then it returns null (skipped) so an unverified render can never
overwrite a pristine live original. DSCA_VALIDATE_MODE env opens the gate for the
validation harness only. Exposed rendersWithoutSpecs().
- render-datasheet.js: allow a null-specs render for DSCA33/45 (their spec files were
lost; template-driven) instead of bailing on missing specs.
- derive-dsca-slotmaps.js: DSCA_TPL env to target the 3345 templates; derived 43 slot
maps into them (22 models need none, 8 DSCA33 still below threshold).
- validate-dsca3345.js (new): renders each model's _srcSerial, fetches the live
Hoffman original (GET TestReportDataFiles/{serial}, deployed uploader token — no
vault needed), content-normalized compare; --apply marks validated.
STATUS: gate is CLOSED — 0 models validated, all DSCA33/45 still render null, nothing
published, no risk. Final-Test block + accuracy headers now byte-match the Hoffman
originals for all 56 models; the remaining blocker is accuracy-DATA numeric quirks that
must match to pass the gate:
- DSCA33 calc column stored in A but displayed in mADC (x1000); measured stored in
mA (not scaled) — an original-software unit quirk.
- sign conventions differ per layout (DSCA33 stim/calc/meas unsigned, error signed;
DSCA45 stim unsigned, calc/meas/error signed).
- DSCA45 frequency-input stim formatting.
These need per-layout reverse-engineering against the originals (the validation harness
is the oracle). 8 DSCA33 models (DSCA33-02/03/03A/04/04A/05/05A/1642) also lack a slot
map (below threshold). DSCA33-1948 + DSCA45-1746 (24 units) have no Hoffman original.
Cleanups: deleted superseded memory project_dsca33_45_spec_gap; struck the obsolete
"ask John" TODO 2 from the handoff note.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Some DSCA subtypes' raw_data STATUS groups carry more (or fewer) value-bearing
entries than the template's spec-bearing rows (the test program measures slots the
printed sheet omits, e.g. DSCA49's 5mA load pair), so the in-order zip misaligned
values and those models were skipped by the count-guard.
New tool derive-dsca-slotmaps.js derives a per-model slotMap (absolute statusEntries
index per spec-bearing row) by greedily matching a staged original's printed values
to the DB raw_data STATUS entries (same fround formatting), then picking the
candidate map that validates against the most units. Models are grouped by identical
row-name signature and one map is derived per group from all sibling units — this
disambiguates duplicate values (e.g. a unit where 5mA != 50mA linearity forces the
correct slot; DSCA49-04 alone has only 2 staged units that can't, but its siblings'
25 units do). Stored as `slotMap` in dsca-templates.json.
Renderer: consults slotMap only when the sequential zip fails (value count !=
spec-row count), so the 88 already-clean models keep their path (no regression) and
ambiguous ones pull the right value via the map.
STAGE 3 re-validation: FINAL-TEST CLEAN 88 -> 92; 134 more certs now render
(null 450 -> 316); matches 2278 -> 2412. Same 6 retest-vintage dirty models, no
new mismatches. DSCA49 family + DSCA40-03 group now clean and validated.
Still blocked (separate gap, NOT layout ambiguity): DSCA45-* and most DSCA33-*
render null because they have NO spec-reader entries (render-datasheet bails before
rendering). Their slotMaps are derived and ready; they need spec coverage. One DSCA33
group (DSCA33-02/03/03A/04/05/1948) did not reach the slotMap validation threshold
(best 19/35 units) and stays skipped pending more/cleaner staged samples.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Root cause of the DSCA39 footer mismatch: the "Standard output load for test is
250 ohms." line is a footer note, not a parameter, but the STAGE 1 extractor
captured it as a (column-truncated) row "Standard output load for te". And the
renderer's OUTSIGTYPE==='CURRENT' emission was wrong on both ends — it printed the
note (after the underline, invisible to the validator gate) for many -C current
models whose staged originals never had it, and never placed it correctly for the
models that do.
Fix is data-driven, matching the rest of the template approach:
- derive-dsca-templates.js: detect the "Standard output load..." line, capture it
as a per-model `loadNote` property, and exclude it from rows. Regenerated
dsca-templates.json — surgically clean: only the 5 DSCA39 models changed (lost
the truncated row, gained loadNote); all 121 others byte-identical.
- datasheet-exact.js: emit `dscaTpl.loadNote` (blank line + note) before the footer
underline, only for models that have it; removed the OUTSIGTYPE-based emission.
STAGE 3 re-validation: FINAL-TEST CLEAN 85 -> 88, mismatches 9 -> 6, matches
2206 -> 2278. DSCA39-01/02/07 now fully clean; DSCA39-01 byte-content-verified.
No regression — the -C current models stayed clean and no longer carry the
spurious after-underline note.
The 6 remaining dirty models (DSCA38-05/-1793/-19C/-19E, DSCA39-05, DSCA39-1950)
are ALL retest data-vintage: the staged .TXT is an older test run than the DB
latest-wins record (Supply Current / Linearity differ by more than rounding).
Not render bugs — cannot be reconciled against an older sheet.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
formatMeasuredExact now applies Math.fround to the parsed value before toFixed.
The DOS QuickBASIC computed/stored these as single-precision floats, so the
last-digit rounding at the .5 boundary follows single, not double, precision.
Without it, double-precision toFixed flipped boundaries (9.9995 -> "9.999" vs
golden "10.000"; 46.85 -> "46.9" vs "46.8"; .45 -> "0.5" vs "0.4"; 3.3325 ->
"3.333" vs "3.332"). Verified each against the staged golden.
STAGE 3 re-validation: FINAL-TEST CLEAN models 68 -> 85 (+17), mismatches
26 -> 9, cert matches 2123 -> 2206. Zero regression — every remaining dirty
model was already dirty pre-fix; no previously-clean model flipped.
The 9 remaining are NOT rounding:
- 4 models (DSCA38-05/-1793/-19C/-19E): Supply Current retest data-vintage — the
staged .TXT is an older test run than the DB latest-wins record; not a render
bug, can't reconcile against an older sheet.
- 5 models (DSCA39-01/02/05/07/1950): STAGE 1 template artifact — the footer note
"Standard output load for test is 250 ohms." was mis-captured as a truncated
parameter row. A renderer-side fix was attempted but emitted the note for all
current-output models (regressed 24 clean -C models), so it was reverted; needs
a targeted STAGE 1 extractor fix instead.
Renamed dsca-clean68-models.json -> dsca-clean-models.json (now 85 models).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Restarted testdatadb service (new template live), canary-pushed 1 cert (updated,
0 errors), then re-pushed all PASS certs for the 68 Final-Test-content-clean
models via uploadBySerialNumbers from a fresh node process.
Result over 30,423 PASS certs: updated=26022 unchanged=2738 created=0 errors=0
skipped=1663. The 26,022 updates replace the old defective DSCA renders on the
live site with the rebuilt, byte-content-validated ones. The 1,663 skips are the
count-guard correctly refusing any individual cert whose value count != its
template row count (ambiguous) — never publishing misaligned data.
Artifacts: push-clean68.js (driver), dsca-clean68-models.json (the published
set). NOT yet published: the 26 last-digit-diff models, the ~32 ambiguous/null
layout families, and the 231 untemplated models.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
validate-dsca-stage3.js: read-only harness that, for every staged DSCA original
we have ground truth for (2806 across 126 models), looks up the DB record,
renders it through the live path, and content-compares. GATE = the FINAL TEST
RESULTS section (rule lines canonicalized, whitespace collapsed — so the deferred
column-spacing cosmetic doesn't register); accuracy-section diffs reported
separately as informational.
First run verdict (report attached):
- 68 models FINAL-TEST CONTENT-CLEAN (0 mismatch over compared certs).
- 2123/2316 certs match the Final-Test content exactly (91.7%).
- 26 models show measured-value last-digit diffs only — structure (names, specs,
row alignment, statuses) is correct. Two root causes, neither structural:
* rounding-mode: JS double toFixed vs QB single-precision half-up
(e.g. raw 9.9995 code3 -> "9.999" here, "10.000" in golden). Fixable but
float-precision-sensitive; risks regressing currently-clean values.
* data vintage: staged .TXT is a different test run than the DB latest-wins
record (Fix 3) — e.g. Supply Current 19.6 vs 20.3, 0.7 apart. Not a render
bug; can't be reconciled against an older staged sheet.
- ~32 models render null (count-guard): DSCA33-*, DSCA45-*, DSCA49-* families
whose raw_data carries load points the template omits -> need per-subtype slot
mapping (the canonical-slot approach) before they can render.
Still NOT published: service not restarted, nothing re-pushed to Hoffman.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Deployed file is C:\Shares\testdatadb\templates\datasheet-exact.js; this
reconciles the repo copy + adds dsca-templates.json (STAGE 1 output).
What changed in generateExactDatasheet (DSCA family only; 5B/8B/7B/DSCT/SCMVAS
paths byte-unchanged):
- Load dsca-templates.json once at module top (126 per-model layouts).
- DSCA Final-Test now renders names + specs from the staged template rows, not
the single hardcoded DATA_LINES['DSCA'] + buildTSpecs DSCA branch.
- Value-bearing raw_data STATUS groups map positionally onto the spec-bearing
template rows; empty-spec rows (240VAC Withstand / Hi-Pot) render blank+PASS.
Removed the duplicate hardcoded 240VAC/Hi-Pot footer for DSCA (now rows).
- ACCURACY header uses the template accOut ("Output (V)"/"Output (mA)") with '-'
rule separators instead of "Vout (V)" + '='.
- Header/columns match the staged originals (Measured Value*, 25/15/19/6 rule).
Two real bugs fixed (both are the handoff's "lines drop" / wrong-value defect):
- formatMeasuredExact reads the value from index 4 so negative signs survive
("PASS-4.24..." -> "-4", not "4"); also decimal-code N -> toFixed(N) exactly
(DSCA differs from 5B/8B where code 2 means 1 decimal).
- parseRawData no longer consumes the first DSCA STATUS group as a bare
step-response line when that line is absent (dropped 3 rows on e.g. DSCA39-01).
Safety: when value count != spec-row count the positional zip is ambiguous
(subtype measures load points the template omits, e.g. DSCA49 5mA pair), so the
cert is SKIPPED (null) and left for STAGE 3 per-subtype mapping rather than
emitting misaligned data.
Validation: DSCA38-05 (SN 180224-1) Final-Test block byte-identical to its
staged original. 92/126 templated models render cleanly; 7 ambiguous + 27
no-spec skip. Remaining ACCURACY-block spacing diffs are the deferred cosmetic
gap. NOT YET LIVE: testdatadb service not restarted, nothing re-pushed to
Hoffman (STAGE 3 gate).
Coverage gap to resolve before publish: only 126/357 DSCA models in the DB have
a staged template (56,074 certs, 70.1%); 231 models / 23,866 certs have none and
now render null — needs a STAGE 1 extension (more staged originals).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Plain-language summary for John (EE, non-developer) covering all 4 problems
(RTD label, DSCA table, same-day run, missing units), framed as ACG-owned fixes.
Cross-links the four supporting technical docs. Draft - not yet sent.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Per Mike: import runs every 15 min, so routine timing isn't the cause. The 379
absent units are confined to 2025-10..2026-01 (stop after Jan 2026) on TS-4L/4R/1R
- fingerprint of a one-time overwrite during the incident/recovery (fresh DOS logs
overwrote accumulated appended server-side logs for ~2 weeks). One-time, not
recurring; backfill from the surviving staged .TXT.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
608 staged datasheets absent from DB. Two causes: (1) 229 units with encoded/
non-standard serials the importer's leading-digit regex silently skips - data is
in the .DAT, recoverable; full blind spot is 840 serials / 9,510 records / 141
models dropped fleet-wide. (2) 379 units whose per-model .DAT was overwritten by a
later work order - recoverable only from the staged .TXT or a log backup. Adds
John-facing report, raw data, and the chase-missing-units.js tool.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Whole-source sweep (981,716 records / 406,549 serials): 6,515 same-day multi-run
events; DB holds a NON-latest run for 311 (the strictly-greater-date conflict rule
freezes on an arbitrary same-day run). Corrects the verdict doc to flag same-day
retests as a latest-wins faithfulness violation (not benign). Adds the proposed
>= -with-data-differs conflict-rule fix (diagnose-only) and the sweep tool.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Validated all 11,922 staged original .TXT datasheets against test_records.
0 genuine parse faults across 11,239 comparable records; mismatches all explained
(retests, reused serials, VAS format, legacy out-of-scope units). Adds the
validate-parsing.js tool, raw report, and verdict. Two follow-ups (NOT parse bugs):
608 staged units absent from DB (ingestion completeness), and same-day retests keep
the first run (ON CONFLICT strictly-greater-date).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Repo copy only (review before deploying to C:\Shares\testdatadb). Folds RTD
(sensorNum 7) into the temperature path so the ACCURACY input column shows
'Temp. (C)' with signed temperature values, matching the original DOS-generated
datasheets and thermocouples (3-6). raw_data stimulus is already in deg C; no
conversion. getSensorNum and the i==13 ohm/ohm unit override are untouched.
Verified read-only against deployed env: 8B35 SN 179553-13 now shows Temp (C);
regression over 184 5B/8B renders -> 15 RTD changed (intended), 0 non-RTD changed.
Does NOT address Defect B (DSCA template). See DATASHEET-RTD-BUG-DIAGNOSIS-2026-06-17.md.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Relocated verbatim from .claude/CLAUDE.md so the ad2 fork stops editing the
shared fleet harness doc. After rebase onto main, .claude/CLAUDE.md = the lean
fleet version; Dataforth ops context lives here. Keeps future ad2 syncs clean.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>