# Test Datasheets Missing From the Database/Website — Findings
**To:** John Lehman (Engineering)
**From:** Mike Swanson, AZ Computer Guru
**Date:** 2026-06-17
**Scope:** Why some tested units have a staged datasheet but no record in testdatadb / on the website.
---
## Summary
I cross-checked **all 11,921 staged datasheet files** (the `.TXT` the test stations produce) against the database. **608 had no matching database record.** They fall into two distinct causes:
| Cause | Units | Recoverable? |
|---|---:|---|
| **1. Encoded / non-standard serial numbers the importer skips** | **229** | **Yes** — the data exists, the importer just doesn't read it |
| **2. One-time log loss during the cryptolocker incident/recovery** | **379** | Yes — from the staged `.TXT`, which still exists on disk |
The first cause is the important one: it is a **software limitation we can fix**, and its true reach is far larger than these 608 — see "Full scope" below.
---
## Cause 1 — Encoded serial numbers are silently skipped (229 units, fixable)
**What happens:** When a serial number is too long for the DOS 8.3 filename, the test program encodes the first two digits as a letter (e.g. `10243-1` is written as `A243-1`; `10` -> `A`). For these units, the serial is stored **with a leading letter** inside the log file:
```
"A243-1","01-21-2025" <- real serial 10243-1, model 5B45-25D
```
The database importer recognizes a record only when the serial **starts with a digit**. A serial that starts with a letter never matches, so the whole record is **silently dropped** — it is never imported, never rendered, never sent to the website.
**Confirmed:** the encoded serials are present in the `.DAT` logs (e.g. `5BLOG\45-25D.DAT` contains `"A243-1","01-21-2025"`), and the decoded form (`10243-1`) appears in no log and in no database row. So the data exists; the importer simply can't read it.
**Of the 608 missing, 229 are this case:**
- 212 are hex-encoded serials (all `A`-prefix, i.e. `10xxx` serials)
- 17 are other non-standard serial formats the same rule rejects (e.g. `TEST-1`, `178540-A1`, `A-1`)
- Stations: TS-11R (142), TS-11L (59), TS-8R (11), TS-8L (17)
- Dates: late 2025 through 2026
- Example models: SCM5B47K-05, SCM5B38-04, SCM5B34-01, 8B45-02, SCM5B36-02, 8B32-01, 5B45-25D, DSCA45-01
**Examples (encoded -> real serial):**
```
A243-1 -> 10243-1 5B45-25D 02-03-2026 TS-11L
A244-1 -> 10244-1 SCM5B30-02 03-26-2026 TS-11L
A276-1 -> 10276-1 DSCA39-05 05-07-2026 TS-11L
A328-1 -> 10328-1 DSCA45-08 02-17-2026 TS-11L
```
### Full scope of this bug (beyond the 608)
The 229 above are only the units that *also* still have a staged `.TXT` on disk. Scanning **every** `.DAT` log across all stations and the central history logs, the importer is dropping:
- **840 distinct encoded serial numbers**
- **9,510 individual test records**
- across **141 models**
- of which **831 of 840 serials are absent from the database**
So this single serial-format limitation is keeping on the order of **~9,500 test results out of the database and off the website.**
**Fix:** teach the importer to (a) accept a serial that starts with a letter and (b) decode it back to its real number (`A243-1` -> `10243-1`) before storing — matching how the longer serials (the `H`-prefix range) are already handled. This is a one-function change to the import parser. It would recover the 229 units here plus the ~9,500-record backlog. (I will write this up as a separate proposed change for review; no code has been changed.)
---
## Cause 2 — One-time log loss during the cryptolocker incident/recovery (379 units)
These have ordinary numeric serials (no encoding issue), but their raw test data is **no longer in any log file** we import from. **This is not an ongoing gap** — the import runs every 15 minutes and everything since has come through cleanly.
**What happened:** the DOS stations append all of a given model's results into a single shared per-model `.DAT` file. During the crypto incident, stations were failing to sync, and in the recovery the appended-to-one-filename behavior wasn't yet understood — so for ~2 weeks, freshly-created logs coming off the DOS machines overwrote the accumulated server-side logs, wiping the earlier history those files held.
**Evidence (date/station fingerprint of a one-time overwrite):** the 379 affected units are confined to **2025-10 → 2026-01 and stop cold after January 2026**, concentrated on three stations:
| Test month | Units | | Station | Units |
|---|---:|---|---|---:|
| 2025-10 | 95 | | TS-4L | 185 |
| 2025-11 | 66 | | TS-4R | 171 |
| 2025-12 | 210 | | TS-1R | 23 |
| 2026-01 | 8 | | | |
**Confirmed example:** units `177097-1 ... 177097-16` (model DSCA33-05, tested 10-17-2025, TS-1R) appear in **no** log file anywhere under the test share. Their model's log (`DSCLOG\33-05.DAT`) now holds a later work order (`178644-*`, tested 02-26-2026) — the older appended history was overwritten; only the staged `.TXT` datasheet survived.
**Recovery:** the rendered datasheet `.TXT` still exists on disk for these units, so they can be backfilled directly from the `.TXT` (store the existing sheet as-is). The raw `.DAT` history is gone (the `Recovery-TEST` backup area the importer references does not exist on this server). Backfilling from the staged `.TXT` is the practical path and recovers all 379.
---
## Recommended actions
1. **Fix the importer's serial handling** (Cause 1) — recovers 229 staged units and ~9,500 total dropped records across 141 models. Highest value, single code change. Proposal to follow for review.
2. **Backfill the 379 incident-era units (Cause 2) from their staged `.TXT` files** — recovers the datasheets that still exist on disk.
3. **Recurrence:** Cause 2 was a one-time incident artifact (the 15-minute import has captured everything since January 2026), so no ongoing process change is required. Worth confirming the current sync no longer overwrites accumulated server-side logs with fresh DOS-side copies.
---
## How this was determined (for the record)
- Compared every `C:\Shares\test\STAGE\**\*.TXT` against `test_records` (serial, model, date, measured results).
- For each missing unit, searched all `.DAT` sources (central HISTLOGS + every station's LOGS, 26,815 files) for the encoded and decoded serial.
- Confirmed encoded serials are present in the logs but skipped by the import regex; confirmed overwritten units are absent from all logs and their model log now holds a newer work order.
- Tools (read-only) committed under `projects/dataforth-dos/datasheet-pipeline/implementation/tools/`; raw data in `MISSING-UNITS-ROOTCAUSE-2026-06-17.txt`.