formatMeasuredExact now applies Math.fround to the parsed value before toFixed. The DOS QuickBASIC computed/stored these as single-precision floats, so the last-digit rounding at the .5 boundary follows single, not double, precision. Without it, double-precision toFixed flipped boundaries (9.9995 -> "9.999" vs golden "10.000"; 46.85 -> "46.9" vs "46.8"; .45 -> "0.5" vs "0.4"; 3.3325 -> "3.333" vs "3.332"). Verified each against the staged golden. STAGE 3 re-validation: FINAL-TEST CLEAN models 68 -> 85 (+17), mismatches 26 -> 9, cert matches 2123 -> 2206. Zero regression — every remaining dirty model was already dirty pre-fix; no previously-clean model flipped. The 9 remaining are NOT rounding: - 4 models (DSCA38-05/-1793/-19C/-19E): Supply Current retest data-vintage — the staged .TXT is an older test run than the DB latest-wins record; not a render bug, can't reconcile against an older sheet. - 5 models (DSCA39-01/02/05/07/1950): STAGE 1 template artifact — the footer note "Standard output load for test is 250 ohms." was mis-captured as a truncated parameter row. A renderer-side fix was attempted but emitted the note for all current-output models (regressed 24 clean -C models), so it was reverted; needs a targeted STAGE 1 extractor fix instead. Renamed dsca-clean68-models.json -> dsca-clean-models.json (now 85 models). Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>